Genie G produces ultrapure water (Type I water) and EDI water (Type II water) from tap water directly. It offers desired solutions for research professionals who work with varieties of applications utilizing Type I ultrapure and Type II pure water in the lab. Quality of ultrapure water and EDI water meet or exceed ASTM, CLSI, CAP, and ISO Type I water and Type II water standards, respectively.

The system is CE/RoHS certified. RephiLe provides full documents support to meet user’s GMP, GSP, GAP, GCP, GLP requirements.


Share

Design & Functions

  • The system can be linked to multiple dispensers via CAN cable or wireless. “1+N” Mode.
  • Automatic temperature compensation allows RO production rate stable over a wide range of temperature.
  • Exceptionally consistent and predictable high purity Type II water from the best in class IonPure EDI (electrodeionization) module.
  • Fully automated system has cleaning, rising, flush and many other functions.
  • System automatically rinses a new RO membrane. User does not need to set special rinse program for a new RO membrane.
  • A bypath automatically sends the RO water to the drain if it does not meet a preset quality standard. The RO drain water is reused to increase the water yield thus it is more environmentally friendly.
  • The main system can be tucked away to save precious bench space since it fits well to be wall-mounted, set on the shelf or under the sink.
  • The Chlorine cleaning and pH cleaning functions keep the maintenance easier and ensure optimal water quality.
  • Leak protector incorporated can prevent damage from a water leakage by shutting the feed water off in case of unexpected leaking.
  • Tank recirculation model guarantees water quality in the tank.

Effective TOC level controlment

  • Built-in 254 nm UV lamp kills bacteria and a 185/254 nm dual wavelength UV lamp reduces TOC level in ultrapure water.
  • A tank Sanitization Module can be equipped to effectively keep microbial growth at a lower level by UV light.
  • On-line TOC monitor based on complete oxidation methods.

Easy Operation and Maintenance

  • Performance history, alarms and alerts information, maintenance data of consumables as well as key parts are logged and traceable from a simple RFID scan at installation.
  • RFID tags ensure perfect placement of consumables and trace their performance.
  • Water quality, operation parameters, the status of the system, dispensers, components, and peripheral devices are stored and displayed on the large color touch screen monitor.
  • Signature verification for maintenance and service.

Cartridges and Parts

1. EDI module

  • Internal Ion-Pure EDI module removes the remaining ions, further reduce the content of organic compounds and has a certain capacity to prevent the growth of bacteria from RO water.
  • Ion exchange resins are continuously regenerated by an electric field. No hazardous chemical regeneration or costly resin replacement is needed.
  • EDI module has a high degree of automation and minimal electricity consumption by using the equivalent of the energy.

2. Cartridge

  • Internal P Pack cartridge removes oxidants, organics, particles and scaling ions to prevent them from fouling the RO membranes and the EDI module.
  • AC Pack contains special activated carbon to remove organic impurities and free chlorines.
  • Ultra purification cartridge is filled with LeFilTM and OrganeFilTM media to remove trace ions and organics.

3. Control console

  • 8-inch console controls system and peripheral devices (Such as leak protector and tank sanitization module). All operations can be done on the console by touching the screen.
  • The control console can be placed on the bench or inside a drawer for further flexibility and space saving.
  • The console screen and dispenser screens are water-proof. You can operate the console and dispenser with latex gloves on.
  • The system has two level password protection on display menu for safety purposes.

4. Dispenser

  • The volumetric function can automatically deliver the water volume you need once it is set up.
  • With the adjusting button on a control console or a dispenser, you can dispense water at the flow rate you need up to 2 liters per minute.
  • A dispenser handle can be set on the dispenser stand, on the main system, or even hanging onto other places to free up maximum bench space.

5. Final Filter

  • A wide range of final filters (optional) is applicable to ensure ultrapure water without particles, bacteria or pyrogen.

6. Level sensor

  • The tank integrated continuous level sensor measures water level within the tank and manages the system to start or stop producing water automatically based on requirements.
  • Water level and quality inside the tank can be viewed from the control console.
Feed Water Requirements
Tap water Municipal water, Conductivity < 2000 μS/cm (1000 ppm)
Operating temperature 5 - 45 ℃
Feed water pressure 1 - 6 bar (15 - 90 psi)
Water Flow Rate
EDI water production rate (@ 25℃) 5, 10, 15 L/hr
EDI water dispensing rate Up to 2.0 L/min
Ultrapure water dispensing rate Up to 2.0 L/min
Product Water Quality
EDI water resistivity (@ 25℃) > 5 MΩ·cm (typically 10 - 15 MΩ·cm)
EDI water TOC* < 30 ppb
Ultrapure water resistivity (@ 25℃) 18.2 MΩ·cm
Ultrapure water TOC* < 5 ppb
Particles in ultrapure water

( > 0.2 μm)

No particles (with a 0.2 μm final filter or RephiBio filter)
Microorganisms in ultrapure water < 0.01 cfu/ml (with a 0.2 μm final filter or RephiBio filter)
Pyrogens in ultrapure water < 0.001 Eu/ml (with a RephiBio filter)
RNase in ultrapure water < 0.5 pg/ml (with a RephiBio filter)
DNase in ultrapure water <10 pg/ml (with a RephiBio filter)
Product Water Quality Stored in Tank ( for tank recirculation models )
Resistivity (@25℃) > 1 MΩ·cm (default), adjustable
Dimensions
Main system dimensions

Width × depth × height

32 × 44 × 54 cm (12.6 × 17.3 × 21.3 in)
Dispenser dimensions

Width × depth × height

21 × 29 × 61 cm (8.3 × 11.4 × 24.0 in)
Weight 20 kg
Input Voltage 110 - 240 VAC
Operating Voltage 24 VDC
Main system power < 200 W

*Product water quality may vary due to local feed water conditions.