Genie G Ultrapure & EDI Lab Water Systems
- LOGIN FOR MORE INFO
Genie G produces ultrapure water (Type I water) and EDI water (Type II water) from tap water directly. It offers desired solutions for research professionals who work with varieties of applications utilizing Type I ultrapure and Type II pure water in the lab. Quality of ultrapure water and EDI water meet or exceed ASTM, CLSI, CAP, and ISO Type I water and Type II water standards, respectively.
The system is CE/RoHS certified. RephiLe provides full documents support to meet user’s GMP, GSP, GAP, GCP, GLP requirements.
Design & Functions
- The system can be linked to multiple dispensers via CAN cable or wireless. “1+N” Mode.
- Automatic temperature compensation allows RO production rate stable over a wide range of temperature.
- Exceptionally consistent and predictable high purity Type II water from the best in class IonPure EDI (electrodeionization) module.
- Fully automated system has cleaning, rising, flush and many other functions.
- System automatically rinses a new RO membrane. User does not need to set special rinse program for a new RO membrane.
- A bypath automatically sends the RO water to the drain if it does not meet a preset quality standard. The RO drain water is reused to increase the water yield thus it is more environmentally friendly.
- The main system can be tucked away to save precious bench space since it fits well to be wall-mounted, set on the shelf or under the sink.
- The Chlorine cleaning and pH cleaning functions keep the maintenance easier and ensure optimal water quality.
- Leak protector incorporated can prevent damage from a water leakage by shutting the feed water off in case of unexpected leaking.
- Tank recirculation model guarantees water quality in the tank.
Effective TOC level controlment
- Built-in 254 nm UV lamp kills bacteria and a 185/254 nm dual wavelength UV lamp reduces TOC level in ultrapure water.
- A tank Sanitization Module can be equipped to effectively keep microbial growth at a lower level by UV light.
- On-line TOC monitor based on complete oxidation methods.
Easy Operation and Maintenance
- Performance history, alarms and alerts information, maintenance data of consumables as well as key parts are logged and traceable from a simple RFID scan at installation.
- RFID tags ensure perfect placement of consumables and trace their performance.
- Water quality, operation parameters, the status of the system, dispensers, components, and peripheral devices are stored and displayed on the large color touch screen monitor.
- Signature verification for maintenance and service.
Cartridges and Parts
1. EDI module
- Internal Ion-Pure EDI module removes the remaining ions, further reduce the content of organic compounds and has a certain capacity to prevent the growth of bacteria from RO water.
- Ion exchange resins are continuously regenerated by an electric field. No hazardous chemical regeneration or costly resin replacement is needed.
- EDI module has a high degree of automation and minimal electricity consumption by using the equivalent of the energy.
2. Cartridge
- Internal P Pack cartridge removes oxidants, organics, particles and scaling ions to prevent them from fouling the RO membranes and the EDI module.
- AC Pack contains special activated carbon to remove organic impurities and free chlorines.
- Ultra purification cartridge is filled with LeFilTM and OrganeFilTM media to remove trace ions and organics.
3. Control console
- 8-inch console controls system and peripheral devices (Such as leak protector and tank sanitization module). All operations can be done on the console by touching the screen.
- The control console can be placed on the bench or inside a drawer for further flexibility and space saving.
- The console screen and dispenser screens are water-proof. You can operate the console and dispenser with latex gloves on.
- The system has two level password protection on display menu for safety purposes.
4. Dispenser
- The volumetric function can automatically deliver the water volume you need once it is set up.
- With the adjusting button on a control console or a dispenser, you can dispense water at the flow rate you need up to 2 liters per minute.
- A dispenser handle can be set on the dispenser stand, on the main system, or even hanging onto other places to free up maximum bench space.
5. Final Filter
- A wide range of final filters (optional) is applicable to ensure ultrapure water without particles, bacteria or pyrogen.
6. Level sensor
- The tank integrated continuous level sensor measures water level within the tank and manages the system to start or stop producing water automatically based on requirements.
- Water level and quality inside the tank can be viewed from the control console.
Feed Water Requirements | |
Tap water | Municipal water, Conductivity < 2000 μS/cm (1000 ppm) |
Operating temperature | 5 - 45 ℃ |
Feed water pressure | 1 - 6 bar (15 - 90 psi) |
Water Flow Rate | |
EDI water production rate (@ 25℃) | 5, 10, 15 L/hr |
EDI water dispensing rate | Up to 2.0 L/min |
Ultrapure water dispensing rate | Up to 2.0 L/min |
Product Water Quality | |
EDI water resistivity (@ 25℃) | > 5 MΩ·cm (typically 10 - 15 MΩ·cm) |
EDI water TOC* | < 30 ppb |
Ultrapure water resistivity (@ 25℃) | 18.2 MΩ·cm |
Ultrapure water TOC* | < 5 ppb |
Particles in ultrapure water
( > 0.2 μm) | No particles (with a 0.2 μm final filter or RephiBio filter) |
Microorganisms in ultrapure water | < 0.01 cfu/ml (with a 0.2 μm final filter or RephiBio filter) |
Pyrogens in ultrapure water | < 0.001 Eu/ml (with a RephiBio filter) |
RNase in ultrapure water | < 0.5 pg/ml (with a RephiBio filter) |
DNase in ultrapure water | <10 pg/ml (with a RephiBio filter) |
Product Water Quality Stored in Tank ( for tank recirculation models ) | |
Resistivity (@25℃) | > 1 MΩ·cm (default), adjustable |
Dimensions | |
Main system dimensions
Width × depth × height | 32 × 44 × 54 cm (12.6 × 17.3 × 21.3 in) |
Dispenser dimensions
Width × depth × height | 21 × 29 × 61 cm (8.3 × 11.4 × 24.0 in) |
Weight | 20 kg |
Input Voltage | 110 - 240 VAC |
Operating Voltage | 24 VDC |
Main system power | < 200 W |
*Product water quality may vary due to local feed water conditions.